We are ready to upload new firmware version files for RGO ONE V6. Changes include improvements in the user interface – added LCD labels, hardware control refinements, added new CAT command:
- Audio peak filter indication On/Off. Now LCD shows the state of the APF. When APF is on – LCD shows “PFon”; When it is off LCD shows “PFof”.
- When CW auto tune procedure is activated with short press of ENC.3 (RIT/XIT encoder) – LCD shows “Auto” so the operator may know that CW autotune procedure has been started. Label “Auto” disappears when CW auto tune procedure is finished.
- Menu 47 (CW keyer auto space feature) is now active even when AF board is missing. This was bug of the software.
- TXG line which is controlled by ALC circuitry is now with better range – 1.3 – 2.6V.
- New CAT command is added – EX command. All menus can be read and set accordingly. EX083 function is added for internal autotuner L,C, HiZ/LoZ parameters set/read.
New Firmware version V1.05 available soon